PERENCANAAN STRUKTUR BETON BERTULANG TAHAN GEMPA GEDUNG HOTEL SOLUNA 4 LANTAI DI JALAN PARIT H. HUSIN II KOTA PONTIANAK

PERENCANAAN STRUKTUR BETON BERTULANG TAHAN GEMPA GEDUNG HOTEL SOLUNA 4 LANTAI DI JALAN PARIT H. HUSIN II KOTA PONTIANAK

  • fajlur Islamiawan Politeknik Negeri Pontianak
  • rasiwan rasiwan
  • Rona Ariansyah
Keywords: Kata Kunci: Struktur beton bertulang, Hotel, Tahan gempa, Respon spektrum, Sistem ganda.

Abstract

Dominated by trade and services, there will be many entrepreneur from local and abroad so that infrastructure
such as hotels is suitable to use as a place to stay or as a meeting room for entrepreneur. Along with the times,
building planning must also meet earthquake-resistant requirements and hence SNI 03-1726-2002 concerning
Earthquake Resistance Planning Standards for Building Structures was made. Earthquake Resistant 4-Storey
Soluna Hotel Building on Parit H. Husin II street, Pontianak City with a height of 22.5 meters from the ground,
reinforced concrete structure. The Medium Moment Bearing Frame System (SRPMM) is used in the calculation
of this building because the results of the Standard Penetration Test show that the building is erected on a soil
with soft conditions (site class SE) and is included in the Seismic Design category (KDS) C. In this method, the
Double System Method is used as the main structural system combined with shear walls. Earthquake load
planning uses the 2017 Indonesian Earthquake Map by utilizing the response spectrum method in accordance
with the Indonesian National Standard (SNI) 1726-2019. The load calculation method used follows the Indonesian
National Standard (SNI) 1727-2020 and the Planning and Loading Guidelines for Building Houses (PPPURG)
1987, the need for structural concrete in building construction must meet the standards set out in SNI 2847-2019.
The calculation results obtained the size of 1 type of plate 12 cm; 2 types of beams 37.5/55 cm, 30/40 cm; 1 type
of column 55/55 cm; staircase and balcony plates 12 cm, 3 types of foundations P3 250 x 250 x 70 cm - pile 9D30
cm; P2 250 x 170 x 70 cm - pile 6D30 cm; P1 170 x 170 x 50 cm - pile 4D30 cm.
Keywords: Reinforced concrete structure, Hotel, Earthquake resistant, Spectrum response, Dual system

References

[1] D. P. Umum, "Pedoman Persyaratan Teknis
Bangunan Gedung," Jakarta: Ditjen Cipta
Karya Departemen Pekerjaan Umum, 2006.
[2] G. Fitriono, "Desain Modifikasi Struktur
Gedung Apartemen Grand Sungkono Lagoon
Tower Caspian dengan Menggunakan
Performance Based Design dan Dual System,"
Institut Teknologi Sepuluh Nopember, 2019.
[3] R. H. Permana, "Analisis BMKG soal Gempa
M 3,5 Kabupaten Sintang," detikcom, [Online].
Tersedia: https://news.detik.com/berita/d-
4911123/analisis-bmkg-soal-gempa-m-35-
kabupaten-sintang. [Diakses 10 September
2022]
[4] A. Setiawan, "Perancangan struktur beton
bertulang berdasarkan SNI 2847: 2013,"
Jakarta: Erlangga, vol. 301, 2016.
[5] Y. Lesmana, "Handbook analisa dan desain
struktur tahan gempa beton bertulang (SPRMB,
SPRMM, SPRMK) berdasarkan SNI 2847:
2019 dan SNI 1726: 2019," ed: Makassar: Nas
Media Pustaka, 2021.
[6] Y. Lesmana, "Handbook Analisa dan Desain
Shear Wall Beton Bertulang Dual System
Berdasarkan SNI 2847: 2019 & SNI 1726:
2019," ed: Makassar: PT Nas Media Indonesia,
2020.
[7] A. Pamungkas and E. Harianti, "Desain Pondasi
Tahan Gempa," Andi, Yogyakarta, 2013.
[8] B. S. Nasional, "Tata cara perencanaan
ketahanan gempa untuk struktur bangunan
gedung dan non gedung," Sni, vol. 1726, p.
2019, 2019.
Published
2023-12-31