PERHITUNGAN STRUKTUR BETON BERTULANG PADA PEMBANGUNAN HOTEL 7 LANTAI DI JALAN AHMAD YANI 2 KABUPATEN KUBU RAYA

PERHITUNGAN STRUKTUR BETON BERTULANG PADA PEMBANGUNAN HOTEL 7 LANTAI DI JALAN AHMAD YANI 2 KABUPATEN KUBU RAYA

  • Hafidza Ulfa Khairunnisa Politeknik Negeri Pontianak
  • rasiwan rasiwan Politeknik Negeri Pontianak
  • iwan supardi Politeknik Negeri Pontianak
Keywords: Analisa Struktur, Hotel 7 lantai, Struktur Gedung

Abstract

Increasing growth of economic in developing product and services that currently happened in kubu raya
district encourage development of hotel planning.
Development of 7th floor hotel building in Ahmad Yani street is expected to increase economy, technology access,
unisolated the area, increase mobility and social contacts of the community activities.
Kubu Raya district is a soft soil area, that is why construction analysis in hotel building needed, to
development of reinforced concrete hotel, it is expected the building fill the safety factor and comfiness. The
analysis did to fulfil that aspect with the applicable regulation such as dead load which refers to the Loading
Planning Guidelines for Houses and Buildings 1987, Indonesian National Standard 1727:2013 used to analyze
wind loads and live loads on buildings, Indonesian National Standard 1726:2019 used to analyse earthquake load
like define the site class, seismic design coefficient, also seismic force resisting system. Indonesian National
Standard 2847:2013 used to design construction material that will used in preliminary design of structural
element, concrete covers, also formula used from slab, beam, column, and foundation.
Increasing growth of economic in developing product and services that currently happened in kubu raya
district encourage development of hotel planning.
Development of 7th floor hotel building in Ahmad Yani street is expected to increase economy, technology access,
unisolated the area, increase mobility and social contacts of the community activities.
Kubu Raya district is a soft soil area, that is why construction analysis in hotel building needed, to
development of reinforced concrete hotel, it is expected the building fill the safety factor and comfiness. The
analysis did to fulfil that aspect with the applicable regulation such as dead load which refers to the Loading
Planning Guidelines for Houses and Buildings 1987, Indonesian National Standard 1727:2013 used to analyze
wind loads and live loads on buildings, Indonesian National Standard 1726:2019 used to analyse earthquake load
like define the site class, seismic design coefficient, also seismic force resisting system. Indonesian National
Standard 2847:2013 used to design construction material that will used in preliminary design of structural
element, concrete covers, also formula used from slab, beam, column, and foundation.
Structural analysis of reinforced concrete 7th floor hotel building in Ahmad Yani 2 street resulting slab
thickness with 12 and 10 cm, beam with 35x 70 cm, 30 x 50 cm, 25 x 45 cm, 15 x 30 cm, 2 type of column with
size 70 x 70cm, 30 x 30cm also distributed to Pile Cap with 5 spunpile diameter 50 cm.

References

[1] Agus Setiawan. (2017). Perancangan Struktur
Beton Bertulang. Erlangga.
[2] Asroni, A. (2017). Kolom Fondasi & Balok T
Beton Bertulang. Surakarta: Muhammadiyah
University Press.
[3] Asroni, A. (2017). Teori Dan Desain Balok Plat
Beton Bertulang. Surakarta: Muhammad
University Press.
[4] Badan Pusat Statistik Kabupaten Kubu Raya.
(Kubu Raya 2020). Data Jumlah Penduduk dan
Pariwisata.
[5] Badan Standardisasi Nasional. (2013). SNI
1727 : 2013. Beban Minimum untuk
Perancangan Bangunan Gedung dan Struktur
Lain. Jakarta: BSN
[6] Badan Standardisasi Nasional. (2013). SNI
2847 : 2013. Persyaratan Beton Struktural untuk
Bangunan Gedung. Jakarta: BSN.
[7] Badan Standardisasi Nasional. (2013). SNI
2847 : 2013. Persyaratan Beton Struktural untuk
Bangunan Gedung. Jakarta: BSN.
[8] Badan Standardisasi Nasional. (2019,
Desember 19). SNI 1726 : 2019. Tata Cara
Perencanaan Ketahanan Gempa untuk Struktur
Bangunan Gedung dan Non Gedung. Jakarta:
BSN.
[9] Direktorat Jendral Perhubungan Udara. (n.d.).
KKOP WEB Angkasa Pura II. Informasi Batas
Ketinggian Bangunan. Informasi Batas
Ketinggian Bangunan.
[10]Eka, I. G. (n.d.). Penentuan Tebal Pelat Lantai
Gedung Yang Ditumpu Pada Keempat Sisinya
Sesuai SNI 2847:2013. 20.
[11]Menteri Pariwisata dan Ekonomi Kreatif
Republik Indonesia. (2013). Standar Usaha
Hotel. Nomor PM.53/HM.001/MPEK/2013.
[12]Pamungkas, A., & Harianti, E. (2013). Desain
Pondasi Tahan Gempa. Yogyakarta: Andi.
[13]Pamungkas, Anugrah; Harianti, Erny;. (2018).
Struktur Beton Bertulang Tahan Gempa.
Yogyakarta: Andi.
Published
2021-12-31